ISOCOM LTD: BSI9000 and CECC20000 Approved Manufacturer

Hutton Close, Crowther Ind Est, Washington, Tyne & Wear NE38 0AH, England
Email: enquiry@isocomoptocouplers.com - Tel: +44 (0)191 4166546 - Fax: +44 (0)191 4155055

Circuit
Features
Description
Absolute Maximum Ratings
Electrical Characteristics

Similar Optocouplers
Home Page


IS620-623, MOC3040-3042
Optically Coupled Bilateral Switch Light Activated Zero Voltage Crossing Triac

Circuit

Features

Photo-Triac Output
7500 V Isolation
400 or 600 Vpeak Blocking Voltage
Low Cost Dual-in-Line Package
Zero Voltage Crossing
U.L. Recognized, File No. E91231

Description

The IS620-623 and MOC304X series are optically coupled isolators consisting of a Gallium Arsenide infrared emitting diode coupled with a monolithic silicon detector performing the functions of a zero crossing bilateral triac mounted in a standard 6-pin dual-in-line package. Surface Mount Option Available.
All electrical parameters are 100% tested. Specifications are guaranteed to a cumulative 0.65% AQL.

Absolute Maximum Ratings (Ta=25°C)

Storage Temperature:
Operating Temperature:
Lead Soldering:
Input-to-Output Isolation Voltage (Peak):
-40°C to +150°C
-40°C to +70°C
260°C for 10s, 1.6mm from case
7500Vac (60Hz, for 5s)

Input Diode

Forward DC Current:
Reverse DC Voltage:
Power Dissipation:
Derate Linearly:
50mA
6V
120mW
1.33mW/°C above 25°C

Output Photo Triac

Off-State Output Terminal Voltage:

RMS Forward Current:
Forward Current (Peak):
Power Dissipation:
Derate Linearly:
400V (MOC3040-3042)
600V (IS620-623)
100mA
1.2A (p.w.=10ms)
300mW
4.0mW/°C above 25°C

Package

Total Power Dissipation:
Derate Linearly:
330mW
4.4mW/°C above 25°C

Electro-optical Characteristics (Ta=25°C)

MOC3040-3042: PBV=400V
IS620-623: PBV=600V

INPUT PARAMETER CONDITIONS MIN TYP MAX UNIT
VF Forward Current IF=30mA

1.5 V
IR Reverse Current VR=6V

100 µA
OUTPUT PHOTO TRIAC
IDRM1 Peak Off-State Current note 1, VDRM=PBV

100 nA
VDRM Peak Blocking Voltage IDRM1=100nA PBV

V
VTM On-State Voltage ITM=100mA (Peak)
IS62x
2.3 3.0 V
MOC304x
2 2.5 V
dV/dt (C) Critical Rate of Rise of Commutating Off-State Voltage

100
V/µs
COUPLED PARAMETER CONDITIONS MIN TYP MAX UNIT
IFT Input Current to Trigger Main Terminal Voltage=3V, note 2
IS620, MOC3040

30 mA
IS621, MOC3041 15 mA
IS622, MOC3042 10 mA
IS623 7 mA

Holding Current, either direction

200
µA

Input-Output Isolation Voltage
7500

Vac
ZERO CROSSING CHARACTERISTICS
VIH Inhibit Voltage IF=Rated IFT; MT-1, MT-2 voltage above which device will not trigger
15 40 V
IDRM2 Leakage Inhibited State IF=Rated IFT, VDRM=PBV, off-state
MOC3040, 3041
100 300 µA
IS620-623, MOC3042 200 µA

Notes

1. Test voltage must be applied with dV/dt rating.
2. Guaranteed to trigger @ IFvalue <= max IFT. Recommended IFlies between max IFTand absolute max IF

Isocom takes great effort to ensure accurate data, but regrettably cannot be held liable for any error on its website. Visit File Lists to confirm old printouts are up-to-date.